lounge wall lighting 143 harley st Friern Electrical

Marylebone

Working with ME Construction, we were involved in this project which was the conversion of a property into two medical units and four residential flats. We were involved in upgrading the electrics of the medical units to ensure that they were up to date and safe, but our main part of the project was with the flats.

The flats were very high spec and our team dealt with the lighting designs, audio visual solutions and the installation of the electrical wiring.

Knightsbridge

This stunning £40 million project is located in one of London’s most exclusive shopping and residential areas and the finished palatial property fits in well within the area. Our team worked alongside Broadlands Construction to ensure that the finish was the height of luxury.

We installed the building management system, designed the lighting and installed CCTV and an intruder alarm system. We also planned and fitted state-of-the-art underfloor heating as well as ensuring Wi-Fi was available throughout the property.

Not only did this project require us to work alongside the time frames of the construction company, but we were importing lighting from Austria, which meant planning ahead and ensuring everything arrived on time so we did not delay the completion date.

Whitefield School

Refurbishment of Dining Hall and Kitchen area. Installation of new 3 phase Distribution board with designated 3 phase supply to provide separate power to new Dining Hall/Kitchen area. 600×600 direct/indirect lay in type light fittings complete emergency lighting to provide adequate escape route lighting. Installation of a Bain-marie, refrigerated units and Till desks. Cat5e cabling to Till positions. Grade B Fire detection and alarm system to BS 5839-6 comprising of Fire detectors and control indicating equipment. Fire shutters and door closer’s interfaced with Fire Alarm system.

Take a look at some of our other projects.

1A South Eaton, Belsize Park

4 bedroom Ground and Lower ground floors Apartment with En-suite bathrooms. Installation of new incoming mains supply in basement, split metering with new Ryefield board and sub-mains to new Apartment. Mixture of bespoke Low voltage and dimmable LED lighting controlled by Crestron Lighting system. Interfaced with under floor heating Audio visual and heating controls. Grade C Fire detection and alarm system to BS 5839-6 comprising of 240V likable smoke and heat detectors. Intruder alarm system complete with PIR movement detectors, door window contacts, break glass detectors and Panic buttons.

Holland Park

Electrical Installation in a 5 bedroom Apartment with En-suite bathrooms on 3 levels complete with Swimming Pool, Cinema room, Gymnasium and Spa Room. Colour 2700 LED and low voltage halogen to create a warm homely feel. Philips Dimmable Lighting system interfaced with Audio Visual and Curtain Blind controls. Grade B Fire detection and alarm system to BS 5839-6 comprising of Fire detectors and control indicating equipment.
Intruder alarm system complete with PIR movement detectors, door window contacts, break glass detectors and Panic buttons.

16 Queens Gate

Electrical Installation in 2 or 4 bedroom Apartments with En-suite Bathrooms. Installation of new incoming mains supply in lower ground vaults to provide new Metering, Ryefield board with sub-mains to each split level Apartment. Dimmable lighting controls by Lutron Lighting with interface to Audio Visual system. Heatmiser under floor heating controls. Bespoke LED and Low Voltage light fittings by John Cullen Lighting. Grade C Fire detection and alarm system to BS 5839-6 comprising of 240V likable smoke and heat detectors. Intruder alarm system complete with PIR movement detectors, door window contacts, break glass detectors and Panic buttons.

Building A&B Camden Market

We spent 10 months working on Stables Market in Camden, London, creating stunning lighting and state of the art electrics for buildings A&B. We designed the whole lighting layout for the 62 offices, working alongside Broadlands Construction to create a bespoke and contemporary working environment, fitting in well with Camden’s eclectic surroundings.

Our team planned and installed a Business Management System (BMS) which had integrated controls for the lighting and heating which can be operated via iPhones and iPads.

Friern Electrical Services were involved from the project start and created intricate plans for the electricals and lighting. We had 25 members of our team working alongside other contractors and the developers to ensure wiring was completed when it should be so that other parts of the job were not delayed.

-Typical construction drawing Lighting E002 and Power E005

-Typical Tender return Q2542 R1 showing how we put together/breakdown our Tenders / Quotations

– Stairwell Emergency lighting calculations

– VO 16 R & Variation Summary Sheet, Typical Variation sheets show customer how we calculate changes to works as we go along

Charing Cross, London

With Broadlands Construction, we worked on converting the top two floors above Foyles Bookstore’s flagship store on Charing Cross Road for 12 months. We converted the two floors into an opulent penthouse apartment.

Our team planned an intricate lighting system to really complement the apartment and installed a state-of-the-art building management system with intelligent controls, making life much easier for the owner. We added to the luxurious feel of the apartment by installing underfloor heating, ensuring there would be no ‘cold spots’ for the owner.

-Typical Construction drawings 5080-E-B8-612 Rev C1 & Legends 5080-E-501

And As Built drgs 5080-E-B8-35-15 RD / 5080-E-B8-35-17 RD

– Final certificate from building control

– Controls commissioning certificate

– NIC & Emergency Lighting Certs

– Risk assessment/Method Statement

– Operation & Maintenance Manual

– H&S